Initial Cured Film Performance on ACT Cold
Rolled Steel Test Panels
Performance on Production Parts or Other Substrates May Vary
Test
Autophoretic® 800 Series
Autophoretic® 700 Series
Autophoretic® 900 Epoxy
Cathodic
Electrocoat
Resin Type
PVDC
Acrylic
Epoxy
Epoxy
Film Thickness (mils)
0.5-1.0
0.5-1.0
0.6-1.0
0.5-1.0
Pencil Hardness
4-7H
H-2H
2H-3H
2H-3H
Gloss @ 60º
5-10
5-15
40 to 60 @ 20º
Varies
T-Bend
0T
2T+
1T-2T
2T+
Reverse Impact
160/ in-lbs
(0.5-0.7 mils)
40 in-lbs
160 in-lbs (0.5-0.7mils)
40 in-lbs
Cross Hatch Adhesion
No Failure
No Failure
No Failure
No Failure
Humidity (1,000 hours)
No Failure
No Failure
No Failure
No Failure
Water Immersion (240 hours)
No Failure
No Failure
No Failure
No Failure
Neutral Salt Spray
Scribe (3mm Creep)
No Scribe (< 10% rust)
600-1000 hrs
2000 hours
336-500 hours
1200 hours
336-500 hours
1000 hours
500->1000
hrs
2000 hours
Cure Temperature
220° F
350°F
365°F
375°F
Temperature Resistance
(Temperature resistance of ACC 800 series is
dependent upon duration and air flow conditions. We recommend life
cycle testing for parts which will be exposed to operating
environments of greater than 200° F)